Use your Serial Number to find your device;
2. When on the main page of the device, click on the option "Edit This Device";
3. Make sure that all the information is correct, specially the Sensor and the Product selected;
4. After that, click on the "Finish" button;
5. Now, click on the "View Details" to go to the device again;
6. In this part, click the "Calibration" tab;
7. Click on the "Update Calibration" button;
8. Insert the tank shape, tank dimensions, the stick reading and the offset (usually its at 0.5 ins, and it's not changed);
Note: If you want to Calibrate the readings on the moment of the installation, refresh the page and select the first option on the last reported call.
9. Confirm that the millivolts per inch (mV/in) value updates at the bottom of the screen. If the value updates correctly, calibration is successfully configured.
10. When this step is finished, press "Save";